GS-3 Multiple-inlet Cyclone
Cat. Nos. 225-100 and 225-103
Description
The GS-3 Cyclone is a 10-mm, lightweight, multiple-inlet, conductive plastic
sampler that uses a standard three-piece casse e and lter for the collection of respira-
ble dust particles. Designed to conform to ISO/CEN particle size-selection criteria (ISO
7708:1995), the GS-3 Cyclone has a 50% cut-point of 4.0 μm (with bias within ISO/OSHA/
NIOSH requirements) at 2.75 L/min* or a 3.5 μm at 3.7 L/min.
In addition, the GS-3
Cyclone meets the requirements in the OSHA proposed rule for silica.
The GS-3 Cyclone can be used with a 25 or 37-mm three-piece casse e with the
corresponding casse e adapter and lter.
Assembly (Figure 1)
The GS-3 Cyclone is supplied fully assembled
with bowl adapter and 37 or 25-mm casse e
adapter dependent upon model (Cat. Nos.
225-100 or 225-103, respectively). Replacement
casse e adapters are available, allowing the
user to adapt whichever model they are using
to another casse e size.
1. Disassemble a three-piece casse e and set
aside inlet section (usually marked “inlet”).
Keep inlet section for closing the casse e
a er sampling.
2. Select a lter and support pad as speci ed
in the sampling method. Place support pad
into casse e outlet and place lter on top
of support pad. Insert casse e ring (middle)
section into casse e outlet. Ensure a rm
seal.
3. Hold cyclone upside down (casse e adapter
facing downward). Insert casse e adapter
into casse e middle ring section. Press until
a rm seal is established.
4. Ensure thumbscrew on cyclone is secure
and that the grit pot remains on the cyclone
body during sampling.
* Calibrated at U.K. Health and Safety Laboratories. Visit
www.skcinc.com/prod/225-100.asp to view the collection
e ciency curve.
Determined using experimental data obtained at ows
from 2.0 to 4.0 L/min.
Operating Instructions
863 Valley View Road, Eighty Four, PA 15330 USA
Tel: 724-941-9701 Fax: 724-941-1369 e-mail: [email protected]
Figure 1
GS-3 Cyclone with Filter
Cassette — Exploded View
Cassette outlet
Support pad
Filter
Cassette ring (middle)
Cassette adapter
(25 or 37 mm, supplied
assembled with cyclone body)
Bowl adapter (supplied
assembled with cyclone body)
Nodule for holder
Retaining tab
Thumbscrew
Cyclone body
Grit pot
Cyclone top
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Operating Instructions

GS-3 Multiple-inlet CycloneCat. Nos. 225-100 and 225-103DescriptionThe GS-3 Cyclone is a 10-mm, lightweight, multiple-inlet, conductive plastic sampl

Page 2 - Calibration

Inserting Cyclone/Cassette Assembly in 225-1Cassette Holder (Figure 2)1. Insert the cyclone body through the large opening of the casse e holder. 2.

Page 3 - Sampling

5. Turn on pump and calibrate to desired fl ow rate following directions in the pump and calibrator operating instructions.Flow rate: 2.75 L/min for

Page 4 - Cleaning

Form 37097 Rev 1401SKC Limited Warranty and Return PolicySKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s