Operating Instructions
Formaldehyde Samplers
For a list of Laboratories, go to www.skcinc.com.
Include the following information when sending your samplers to be analyzed.
Uptake rate (μg/ppm-hr) and Standard deviation (μg)
This data is serial number speci c and appears on the labels in the package.
Personal Samplers Catalog Nos. 526-200 (STEL) and 526-201 (PEL)
1. Remove sampler from bag.
2. Record date, start time, temperature, and ID number on the sampler label.
3. Peel off START label and clip the sampler on or near a worker's collar.
4. Peel off STOP label from back of sampler when testing time is over. Center label over sampling hole on front of sampler and
press to seal.
5. Record date, stop time, and temperature on label.
6. Send sampler(s) to an accredited laboratory (see www.skcinc.com for lab list) for analysis using the chromotropic acid assay
method. Samples should be analyzed with 30 days of exposure. For more details, contact SKC Technical Support at 724-941-9701
or go to www.skcinc.com.
Note: SKC STEL Samplers are designed to measure the formaldehyde STEL in the U.S. of 2 ppm. These samplers do not have the
sensitivity required to detect the ACGIH TLV
®
Ceiling value of 0.3 ppm with a 15-minute sample.
Note: If sampling in an atmosphere containing formalin, see www.skcinc.com/instructions/1795.pdf, Reference 2.
Area Sampler Catalog No. 526-100
1. Remove all materials from the Formaldehyde kit.
2 samplers
2 mounting pins
2 identi cation labels
2. Decide where to hang the sampler. For buildings with a large indoor area or with more than one oor, use more than one sampler.
3. Complete identi cation labels for each sampler. Record location, start date, and start time (circling AM or PM). Then, place a label
on each sampler.
4. Remove the cap from the sampler and place it on the opposite end of the vial to start the test. Hang the sampler by pushing the
mounting pin through the ribbon and into the mounting surface (e.g., door jamb, ceiling). Make sure that the sampler is at least
24 inches (61 cm) away from any wall and that it is not subjected to strong drafts from windows or outside doors.
5. Leave sampler hanging undisturbed for 120 - 168 hours (5 - 7 days).
6. Remove sampler, place the cap tightly over the open end, and record the stop date and stop time (circling AM or PM) on the
sampler label when test period is over. Repeat for each sampler.
7. Send sampler(s) to an accredited laboratory (see www.skcinc.com for lab list) for analysis using the chromotropic acid assay
method. Samples should be analyzed within 30 days of exposure. For more details, contact SKC Technical Support at
724-941-9701 or go to www.skcinc.com.
Note: The linear measuring range for 526-100 samplers is 0.01 to 3.0 ppm.
Note: If sampling in an atmosphere containing formalin, see www.skcinc.com/instructions/1795.pdf, Reference 2.
SKC Limited Warranty and Return Policy
SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability and the buyers exclusive remedy. To view
the complete SKC Limited Warranty and Return Policy, go to h p://www.skcinc.com/warranty.asp.
Form #37719 Rev 1102
863 Valley View Road, Eighty Four, PA 15330 USA
Tel: 724-941-9701 Fax: 724-941-1369 e-mail: [email protected]
Vue de la page 0
1

Résumé du contenu

Page 1

Operating InstructionsFormaldehyde SamplersFor a list of Laboratories, go to www.skcinc.com.Include the following information when sending your sample

Commentaires sur ces manuels

Pas de commentaire